Volume 40 Issue 3
Sep.  2026
Turn off MathJax
Article Contents
YAN Xiyan, FENG Yan, WANG Haoxiang, ZHANG Hua. Analysis method of wearable fiber grating gait monitoring device[J]. Journal of Shanghai University of Engineering Science, 2026, 40(3): 348-354. doi: 10.12299/jsues.25-0075
Citation: YAN Xiyan, FENG Yan, WANG Haoxiang, ZHANG Hua. Analysis method of wearable fiber grating gait monitoring device[J]. Journal of Shanghai University of Engineering Science, 2026, 40(3): 348-354. doi: 10.12299/jsues.25-0075

Analysis method of wearable fiber grating gait monitoring device

doi: 10.12299/jsues.25-0075
  • Received Date: 2025-03-11
  • Publish Date: 2026-09-30
  • A synergistic and accurate monitoring method combining fiber Bragg grating (FBG) sensor and a LabVIEW-based gait monitoring system was established according to the characteristics of FBG sensors. A wearable FBG knee and leg motion monitoring device was designed according to the different physiological structures of the knee and calf. The feasibility of the differential method for eliminating temperature errors was verified by skeletal model experiments. Calibration experiments on the human knee and calf were conducted, and the average sensitivity of the knee was 3.85 pm/(°), and the average sensitivity of the calf was 4.05 pm/(°), which demonstrates that the FBG wearable device and the LabVIEW gait monitoring system are capable of monitoring the motion angles of the knee and calf. The LabVIEW gait monitoring system monitored the theoretical step distance, the distance between the knee and the calf, the distance between the knee and the calf, and the distance between the knee and the calf. The relative error between the theoretical step distance and step height parameters and the actual parameters obtained by the LabVIEW gait monitoring system is 5.525%, and the step height error is 4.750%. Experimental results indicate that the LabVIEW gait monitoring system and the FBG wearable device can provide technical support for monitoring human gait parameters.
  • loading
  • [1]
    Song Y, Liu T J, Wang F L, et al. Wearable capacitive pressure sensors based on porous sponge dielectric materials for gait analysis and identity recognition[J] . Advanced Materials Technologies, 2025, 10(11): 2401768. doi: 10.1002/admt.202401768
    [2]
    Cheng Z H, Wen Y Z, Xie Z N, et al. A multi-sensor coupled supramolecular elastomer empowers intelligent monitoring of human gait and arch health[J] . Chemical Engineering Journal, 2025, 504: 158760. doi: 10.1016/j.cej.2024.158760
    [3]
    Lallès A P, Moucheboeuf G, Doat E, et al. IMU calibration effect on lower limbs kinematics against optical motion capture in post-stroke gait[J] . IRBM, 2025, 46(1): 100873. doi: 10.1016/j.irbm.2024.100873
    [4]
    Zhao L L, Jia S C, Fang C Y, et al. Machine learning-assisted wearable triboelectric-electromagnetic sensor for monitoring human motion feature[J] . Chemical Engineering Journal, 2025, 503: 158637. doi: 10.1016/j.cej.2024.158637
    [5]
    Gao Y Y, Zong R S, Feng J Y, et al. Flexible self-powered and self-sensing shoes based on aeroelastic structure for application in human motion monitoring[J] . Journal of Power Sources, 2025, 638: 236626. doi: 10.1016/j.jpowsour.2025.236626
    [6]
    胡高童. 基于无线智能鞋垫的人体运动状态识别方法研究[D] . 武汉: 武汉纺织大学, 2024.
    [7]
    谢俊枭, 赵欢, 曹军义, 等. 帕金森病步态的可穿戴多源数据采集与特征识别方法[J] . 西安交通大学学报, 2023, 57(6): 29 − 38.
    [8]
    彭爽. 基于惯性传感器的脑卒中患者家用步态采集系统研究[D] . 重庆: 重庆医科大学, 2020.
    [9]
    Gui X, Zeng F H, Gao J, et al. Detection of Aircraft wing icing and de-icing by optical fiber sensing with FBG array[J] . Measurement, 2025, 247: 116748. doi: 10.1016/j.measurement.2025.116748
    [10]
    秦驰. 用于足踝矫形器的埋入式光纤传感器[D] . 哈尔滨: 哈尔滨工程大学, 2024.
    [11]
    Song X B, Fan Y W, Tang X Y. FBG-based wearable sensors and devices in the healthcare field: A review[J] . Optics & Laser Technology, 2025, 181: 111920. doi: 10.1016/j.optlastec.2024.111920
    [12]
    Zhou X, Wang W J, Hui Y P, et al. Real-time human posture recognition using embedded optical fiber sensors and machine learning[J] . IEEE Transactions on Instrumentation and Measurement, 2025, 74: 2508609.
    [13]
    Yi P, Luo B B, Wu D C, et al. Design and gesture recognition of wrist joint posture sensor based on fiber Bragg gratings[J] . IEEE Sensors Journal, 2024, 24(23): 39050 − 39058. doi: 10.1109/JSEN.2024.3481013
    [14]
    Zhang C, Zhou H Y, Nong H C, et al. FBG-SenseGlove: a digital twin data glove for underwater gesture recognition using deep learning[J] . IEEE Sensors Journal, 2025, 25(2): 8347 − 8354. doi: 10.1109/jsen.2025.3532601/mm1
    [15]
    Qiu Z C, Zhang Y F, Fan X Y, et al. Ultra-low frequency three-axis FBG accelerometer for seismic monitoring based on multiple flexible beams[J] . Measurement, 2025, 248: 116947. doi: 10.1016/j.measurement.2025.116947
    [16]
    王昊祥, 冯艳, 潘睿智, 等. 光纤光栅波电转换的人机仿生跟随[J] . 光学精密工程, 2023, 31(23): 3414 − 3425. doi: 10.37188/OPE.20233123.3414
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(8)  / Tables(2)

    Article Metrics

    Article views (45) PDF downloads(10) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return