Experimental study on dehumidification performance of dual cold source dehumidifier with exhaust air heat recovery
-
摘要: 提出一种带有排风热回收功能的双冷源除湿机,将室内排风的冷量回收用于新风的降温。通过实验研究除湿机的除湿性能,并研究不同风量、不同供水温度对除湿机除湿性能的影响。研究得出:在供水流量1.7 m3/h、压缩机功率0.8 kW、供水温度13 ℃、风量350 m3/h的工况下,全新风除湿模式送风口含湿量可达7.6 g/kg,室内循环除湿模式送风口含湿量可达7.4 g/kg。降低风量或供水温度均会提高除湿机的除湿性能。Abstract: A dual cooling source dehumidifier with exhaust heat recovery function was proposed, which recovers the cooling capacity of indoor exhaust for fresh air cooling. The dehumidification performance was experimentally investigated, along with the effects of various air volumes and water supply temperatures. The results show that under the conditions of a water supply flow rate of 1.7m3/h, compressor power of 0.8 kW, water supply temperature of 13 ℃, and air flow rate of 350 m3/h, the moisture content at the air supply outlet can reach 7.6 g/kg in the fresh air dehumidification mode, and 7.4 g/kg in the indoor circulation dehumidification mode can reach g. Reducing the air volume or lowering the water supply temperature will improve the dehumidification performance of the dehumidifier.
-
Key words:
- dehumidification /
- double cold sources /
- heat recovery /
- dehumidification capacity
-
表 1 实验设备参数表
Table 1. Parameter table of experimental equipment
设备名称 参数 数值 型号 双冷源除湿机 额定风量/(m3·h−1) 350 KOCA
ECH350额定功率/kW 0.8 空气源热泵主机 额定制冷量/kW 9.4 McQuay
MACO30ER5额定制冷功率/kW 3.1 供水流量/(m3·h−1) 1.7 -
[1] 刘尚杰, 赵华东, 段玥晨, 等. 温湿度调节机的冷凝除湿性能研究[J] . 低温与超导, 2021, 49(6): 81 − 87. [2] 李江波, 陈柳. 双级热管转轮除湿空调系统性能研究[J] . 低温与超导, 2019, 47(10): 62 − 67, 76. doi: 10.16711/j.1001-7100.2019.10.013 [3] 宗天晴, 傅允准. 热泵型低温再生转轮除湿新风机组除湿性能试验研究[J] . 流体机械, 2023, 51(4): 10 − 17. [4] 王智楷, 李征涛, 于号, 等. 间接蒸发冷却结合除湿机系统性能分析[J] . 化学工程, 2023, 51(6): 34 − 38, 44. doi: 10.3969/j.issn.1005-9954.2023.06.007 [5] 潘钰婷. 双冷源全新风空气处理机组稳态仿真研究[J] . 低温与超导, 2023, 51(3): 75 − 80. [6] 阿曼古丽·开恩斯, 成家豪, 曹祥, 等. 一种基于四换热器构型的整体式热泵热回收型新风除湿机[J] . 制冷学报, 2022, 43(4): 113 − 119. doi: 10.3969/j.issn.0253-4339.2022.04.113 [7] 刘帅领, 马国远, 许树学, 等. 蒸发器冷冻除湿特性模拟分析与优化研究[J] . 制冷学报, 2020, 41(2): 15 − 21, 69. doi: 10.3969/j.issn.0253-4339.2020.02.015 [8] 李鹏魁, 傅允准. 辐射空调专用的两级新风除湿机性能测试与分析[J] . 流体机械, 2019, 47(1): 70 − 74. doi: 10.3969/j.issn.1005-0329.2019.01.013 [9] 张龙爱, 王传华, 屈清杲, 等. 双冷源热回收调温型冷却除湿系统设计及实验研究[J] . 制冷学报, 2021, 42(4): 83 − 90, 115. [10] GE F H, WANG C. Exergy analysis of dehumidification systems: a comparison between the condensing dehumidification and the desiccant wheel dehumidification[J] . Energy Conversion and Management, 2020, 224: 113343. [11] TANG C L, VAFAI K, GU C H, et al. Experimental investigation of dehumidification performance of a vapor compression refrigeration system[J] . International Communications in Heat and Mass Transfer, 2022, 137: 106282. doi: 10.1016/j.icheatmasstransfer.2022.106282 [12] 宗天晴, 王永彬, 曹振, 等. 双冷源新风机组除湿性能测试研究[J] . 流体机械, 2022, 50(4): 8 − 14. doi: 10.3969/j.issn.1005-0329.2022.04.002 [13] YANG T Y, GE T S. Experimental investigation on a compact fresh air humidification/dehumidification system based on desiccant coated heat pump[J] . International Journal of Refrigeration, 2023, 150: 59 − 67. doi: 10.1016/j.ijrefrig.2023.02.005 [14] LI W Z, YIN Y G, WANG Y K. Performance evaluation of a heat pump-driven liquid desiccant dehumidification system integrated with fresh air supply[J] . Energy and Buildings, 2022, 275: 112473. doi: 10.1016/j.enbuild.2022.112473 [15] PENG D G, CAO Z. Modeling and performance analysis of a hybrid-connected two-stage liquid dehumidification fresh air system based on CaCl2/LiCl double solution[J] . Applied Thermal Engineering, 2021, 199: 117529. doi: 10.1016/j.applthermaleng.2021.117529 -
下载: